Menu Close
Menu Close
Close

PRODUCTS

A New Standard
in Vascular Care

ALITAMED builds products that put patients first.

Coronary IVL Catheter™

01

Coronary IVL Catheter™

Coronary Catheter

For moderate to severe calcified coronary lesions, the catheter
fractures the plaque to help restore vessel compliance.

Precise Lesion Access

An ultra-slim catheter smoothly accesses even challenging calcified lesions.

Broad Indication Range

A lineup of 14 catheter types covers a wide range of lesions.

Calcified Plaque Fracture

Safely fractures calcified plaque with acoustic shockwaves.

Adjustable Fracture Rate

Restores vessel compliance by adjusting the shockwave frequency according to the degree of calcification (1/1.5/2 Hz).

Coronary IVL Catheter™ Specifications

Product NameBalloonShaft
Balloon Length
(mm)
Inflated Outer Diameter
(mm)
Nominal Pressure
(atm)
Distal Outer Diameter
(mm)
Proximal Outer Diameter
(mm)
Working Length
(mm)
CIVL-12-250122.5080.980.751,380
CIVL-12-2752.75
CIVL-12-3003.00
CIVL-12-3253.25
CIVL-12-3503.50
CIVL-12-3753.75
CIVL-12-4004.00
CIVL-20-250202.50
CIVL-20-2752.75
CIVL-20-3003.00
CIVL-20-3253.25
CIVL-20-3503.50
CIVL-20-3753.75
CIVL-20-4004.00

※ Maximum total pulses per catheter when connected to the generator: 120.

※ Consecutive pulses per cycle: 10.

Peripheral IVL Catheter™

02

Peripheral IVL Catheter™

Peripheral Catheter

For peripheral artery disease lesions, including those in the superficial femoral artery, widens the vessel lumen to restore blood flow.

Peripheral Artery Disease

For peripheral artery disease lesions, including those in the superficial femoral artery.

Wide Vessel Diameter Range

For lesions with a vessel diameter of 4.0–7.0 mm.

Lumen Expansion

Fractures calcified plaque
to widen the narrowed vessel lumen.

Blood Flow Restoration

Helps restore blood flow
to the lower limbs through the widened vessel.

Peripheral IVL Catheter™ Specifications

ModelBalloonShaft
Balloon Diameter
(mm)
Balloon Length
(mm)
Crossing Profile
(inch)
Compatible Sheath
(Fr)
Working Length
(cm)
PIVL-60-3503.5600.0546F135
PIVL-60-4004.00.054
PIVL-60-4504.50.057
PIVL-60-5005.00.061
PIVL-60-5505.50.062
PIVL-60-6006.00.065
PIVL-60-6506.50.0667F
PIVL-60-7007.00.068

※ Maximum total pulses per catheter when connected to the generator: 300.

※ Consecutive pulses per cycle: 30 (at 2 Hz).


AlitaPulse One™

03

AlitaPulse One™

IVL Generator

A dedicated generator for AlitaPulse catheters
that generates localized shockwaves and delivers optimal energy.

Dedicated Catheter Generator

A dedicated generator designed
specifically for ALITAMED catheters.

Precise Energy Control

Precisely controls energy delivery to target calcified lesions while minimizing vessel damage.

Versatile Pulse Modes

Delivers the optimal pulse for the characteristics of each lesion.

High-Visibility Display

View procedure progress and key parameters at a glance.

AlitaPulse One™ Specifications

Pulse Output Voltage1,000 V ~ 3,000 V ± 10%
Pulse Width< 20 μs
Pulse Output Frequency1 ± 0.2 Hz
Pulse Output Voltage (Catheter Connected)2,300 V ± 10
AI Solution

04

AI Solution

AI assesses the fracture status of calcified lesions in real time during the procedure, supporting precise, patient-tailored treatment.

Detailed information on the AI solution is coming soon.