PRODUCTS
A New Standard
in Vascular Care
ALITAMED builds products that put patients first.
01
Coronary IVL Catheter™
Coronary Catheter
For moderate to severe calcified coronary lesions, the catheter
fractures the plaque to help restore vessel compliance.
Precise Lesion Access
An ultra-slim catheter smoothly accesses even challenging calcified lesions.
Broad Indication Range
A lineup of 14 catheter types covers a wide range of lesions.
Calcified Plaque Fracture
Safely fractures calcified plaque with acoustic shockwaves.
Adjustable Fracture Rate
Restores vessel compliance by adjusting the shockwave frequency according to the degree of calcification (1/1.5/2 Hz).
Coronary IVL Catheter™ Specifications
| Product Name | Balloon | Shaft | ||||
|---|---|---|---|---|---|---|
| Balloon Length (mm) | Inflated Outer Diameter (mm) | Nominal Pressure (atm) | Distal Outer Diameter (mm) | Proximal Outer Diameter (mm) | Working Length (mm) | |
| CIVL-12-250 | 12 | 2.50 | 8 | 0.98 | 0.75 | 1,380 |
| CIVL-12-275 | 2.75 | |||||
| CIVL-12-300 | 3.00 | |||||
| CIVL-12-325 | 3.25 | |||||
| CIVL-12-350 | 3.50 | |||||
| CIVL-12-375 | 3.75 | |||||
| CIVL-12-400 | 4.00 | |||||
| CIVL-20-250 | 20 | 2.50 | ||||
| CIVL-20-275 | 2.75 | |||||
| CIVL-20-300 | 3.00 | |||||
| CIVL-20-325 | 3.25 | |||||
| CIVL-20-350 | 3.50 | |||||
| CIVL-20-375 | 3.75 | |||||
| CIVL-20-400 | 4.00 | |||||
※ Maximum total pulses per catheter when connected to the generator: 120.
※ Consecutive pulses per cycle: 10.
02
Peripheral IVL Catheter™
Peripheral Catheter
For peripheral artery disease lesions, including those in the superficial femoral artery, widens the vessel lumen to restore blood flow.
Peripheral Artery Disease
For peripheral artery disease lesions, including those in the superficial femoral artery.
Wide Vessel Diameter Range
For lesions with a vessel diameter of 4.0–7.0 mm.
Lumen Expansion
Fractures calcified plaque
to widen the narrowed vessel lumen.
Blood Flow Restoration
Helps restore blood flow
to the lower limbs through the widened vessel.
Peripheral IVL Catheter™ Specifications
| Model | Balloon | Shaft | |||
|---|---|---|---|---|---|
| Balloon Diameter (mm) | Balloon Length (mm) | Crossing Profile (inch) | Compatible Sheath (Fr) | Working Length (cm) | |
| PIVL-60-350 | 3.5 | 60 | 0.054 | 6F | 135 |
| PIVL-60-400 | 4.0 | 0.054 | |||
| PIVL-60-450 | 4.5 | 0.057 | |||
| PIVL-60-500 | 5.0 | 0.061 | |||
| PIVL-60-550 | 5.5 | 0.062 | |||
| PIVL-60-600 | 6.0 | 0.065 | |||
| PIVL-60-650 | 6.5 | 0.066 | 7F | ||
| PIVL-60-700 | 7.0 | 0.068 | |||
※ Maximum total pulses per catheter when connected to the generator: 300.
※ Consecutive pulses per cycle: 30 (at 2 Hz).
03
AlitaPulse One™
IVL Generator
A dedicated generator for AlitaPulse catheters
that generates localized shockwaves and delivers optimal energy.
Dedicated Catheter Generator
A dedicated generator designed
specifically for ALITAMED catheters.
Precise Energy Control
Precisely controls energy delivery to target calcified lesions while minimizing vessel damage.
Versatile Pulse Modes
Delivers the optimal pulse for the characteristics of each lesion.
High-Visibility Display
View procedure progress and key parameters at a glance.
AlitaPulse One™ Specifications
| Pulse Output Voltage | 1,000 V ~ 3,000 V ± 10% |
|---|---|
| Pulse Width | < 20 μs |
| Pulse Output Frequency | 1 ± 0.2 Hz |
| Pulse Output Voltage (Catheter Connected) | 2,300 V ± 10 |
04
AI Solution
AI assesses the fracture status of calcified lesions in real time during the procedure, supporting precise, patient-tailored treatment.
Detailed information on the AI solution is coming soon.